Osburn AC01340 Manual do Utilizador Página 8

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 20
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 7
8
6
Install the heat distribution blower in a location where, you will have access for
maintenance and somewhere the fan’s noise will not be disturbing.
*Note: The heat distribution blower must be positioned at a minimum distance of 3 feet
from the fireplace and outside of its enclosure.
*Note: The length of the insulated flexible pipe between the fan and the air outlet must
be no less than 12 feet.
*Note: A minimum clearance to combustible materials of 2 inches from the heat
distribution blower is required.
*Note: The heat distribution blower can be installed horizontally, vertically or at any
angle.
Vista de página 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 19 20

Comentários a estes Manuais

Sem comentários