READ AND KEEP THIS MANUAL FOR REFERENCE
45111A
Printed in Canada 12-06-2015
OWNER`S MANUAL
2400 INSERT (OB02401 model)
US ENVIRONMENTAL PROTECTION
AGENCY PHASE II CERTIFIED
WOOD INSERT
Verified and tested following
ULC S628 and UL 1482 Standards
by an accredited laboratory
Manufactured by: STOVE BUILDER INTERNATIONAL INC..
250, rue de Copenhague, Saint-Augustin-de-Desmaures (Quebec) G3A 2H3
After-sale service: 418-908-8002 E-mail: tech@sbi-international.com
www.osburn-mfg.com
This manual is available for free download on the manufacturer’s web site. It is a copyrighted
document. Re-sale is strictly prohibited. The manufacturer may update this manual from time
to time and cannot be responsible for problems, injuries, or damages arising out of the use of
information contained in any manual obtained from unauthorized sources.
Vista de página 0
1 2 3 4 5 6 ... 33 34

Resumo do Conteúdo

Página 1 - 2400 INSERT (OB02401 model)

READ AND KEEP THIS MANUAL FOR REFERENCE 45111A Printed in Canada 12-06-2015 OWNER`S MANUAL 2400 INSERT (OB02401 model) US ENVIRONMENTAL PRO

Página 2

10 2.6 Positioning the unit In addition to ensuring compliance of the masonry fireplace hearth extension (see Compliance of the masonry fireplace in

Página 3 - TABLE OF CONTENTS

11 If a non-combustible material floor protection needs to be added in front and level with the hearth extension masonry fireplace (see Figure 2.

Página 4

12 The use of an R value is convenient when more than one material is going to be used in the hearth extension to cover the combustible surface.

Página 5

13 The more extended the insert, the greater the heat transfer to the room. When installed as an extended insert, the front edge of the air jacket

Página 6

14 Thermal characteristics of common floor protection materials* MATERIAL CONDUCTIVITY (k) PER INCH RESISTANCE (R) PER INCH THICKNESS Micore® 160 0.

Página 7 - 2.0 INSTALLATION

15 MINIMUM MASONRY OPENING J 23 1/2" (597 mm) K 31 5/8" (803 mm) L 16 1/4" (412 mm) CLEARANCES F 14” (356 mm) G 8” (203 mm) H 2

Página 8

16 2.8 Connector installation A masonry flue connector may provide acceptable performance (Figure 2.8a); however, we recommend the use

Página 9 - SHELF POSITIONING

17 2.8.1 Chimney liner installation To install of the chimney liner, the preferred methods are those found in Section 2.8.1.1. Use a liner offset ada

Página 10

18 2.8.1.2 If the chimney liner does not align with the insert’s flue outlet: You can get a liner offset adapter (AC01370), sold separately. If you m

Página 11

19 C. Place the slide onto the faceplate so that the bends of the faceplate pieces go inside of the slide. 2400 INSERT FACEPLATE BOLT ASSEMBLY: Cont

Página 12

2 INTRODUCTION SBI INC., one of the most important wood stove and fireplace manufacturers in Canada, congratulates you on your purchase

Página 13

20 Back view of faceplate Figure 2.9d Lift the insert into the fireplace. Square the insert to the face of the fireplace by adjusting the leveli

Página 14

21 2.10 Baffle & brick installation CAUTION: Operation of your Osburn insert without the baffle may cause unsafe and hazardous temperature con

Página 15

22 Figure 2.10a 1- First, install the rear secondary air tube (B) in the firebox. Refer to figure 4.5: ‘’secondary air tube replacem

Página 16

23 Figure 2.10b ITEM PIECE # DESCRIPTION QTY 1 29020 4 1/2" X 9" X 1 1/4'' REFRACTORY BRICK 12 2 PL36058 4" X 9"

Página 17

24 3.0 OPERATION 3.1 Safety information 1. This insert is designed for safe operation WHEN BURNING CORDWOOD ONLY. Altering or modifying

Página 18

25 10. Never operate the insert with the door open, or cracked slightly open, except briefly during the lighting operation, and during refuelling

Página 19

26 Common Heating Values of Cordwood Hardwoods Million Btu/Cord Softwoods Million Btu/Cord Birch 23.6 Douglas Fir 20.6 White Oak 28.3 Hemlock

Página 20

27 6. Ideally the large kindling should be burned until a thick bed of red embers is obtained. At that point, add cordwood fuel and continue to oper

Página 21

28 Refuelling technique is important for good performance. The best efficiency and performance from your insert can be achieved by adding partial loa

Página 22

29 4.0 MAINTENANCE 4.1 Care and cleaning Clean the insert frequently so that soot, ash and creosote do not accumulate. Do not attempt to clean th

Página 23

3 TABLE OF CONTENTS 1.0 PRE-INSTALLATION REQUIREMENTS ... 4 1.1 MASON

Página 24 - 3.0 OPERATION

30 4.3 Chimney cleaning Regular chimney maintenance, as well as good burning practices, are required to prevent chimney fires. The ch

Página 25 - ORDWOOD

31 4.5 Secondary air tube replacement (see Figure 4.5) 1. Remove cotter pin at LH end of tube. 2. Slide tube to right and lower tube end below LH

Página 26

32 5.0 TROUBLESHOOTING Symptom Possible Cause Corrective Action I Smoke in room 1. Down draft 1. Upgrade chimney 2. Chimney blo

Página 27

33 6.0 SPECIFICATIONS TEST STANDARDS ULC S628 (CSA B366.2) residential UL 1482 residential Oregon Department of Environmental Quality U.S. Env

Página 28

34 OSBURN LIMITED LIFETIME WARRANTY The warranty of the manufacturer extends only to the original retail purchaser and is not transferable. This warr

Página 29 - 4.0 MAINTENANCE

4 1.0 PRE-INSTALLATION REQUIREMENTS 1.1 Masonry fireplace requirements The masonry fireplace must meet the minimum code requirements, or NFPA 211 or

Página 30

5 1.2 Venting requirements The flue is a critical component to a satisfactory installation. Your insert will attain its best perfor

Página 31

6 1.3 Door overlay installation In order to complete the assembly of your Osburn 2400 wood insert, you need to install the door overlay. See figure

Página 32 - 5.0 TROUBLESHOOTING

7 2.0 INSTALLATION 2.1 Safety information NOTE: THIS APPLIANCE IS NOT RECOMMENDED FOR USE IN A HOME IF AN OCCUPANT HAS ANY RESPIRATORY OR ANY OTHE

Página 33 - 6.0 SPECIFICATIONS

8 2.2 Installation instructions Inspect the masonry fireplace according to the safety information and fireplace requirements and have it cleaned and/

Página 34

9 2.4 The masonry fireplace's draft control system If the fireplace's draft control system is to remain in the masonry fireplace, it must b